REF PD是否正常? 范围是多少? 视力是多少?

\u773c\u79d1\u68c0\u67e5\u5355\u600e\u4e48\u770b\uff1f

\u3000\u3000\u5475\u5475\uff0c\u4f60\u7684\u8981\u6c42\u8fd8\u633a\u9ad8\u7684\uff01\u4eca\u5929\u6709\u65f6\u95f4\u5c31\u597d\u597d\u7ed9\u4f60\u89e3\u91ca\u4e00\u4e0b\u4e86\uff01

\u3000\u3000\u89c9\u5f97\u89e3\u91ca\u7684\u5230\u4f4d\u5c31\u7ed9\u52a0\u5206\u5440\uff01

\u3000\u3000REF.DATA
\u3000\u3000VD:12.00 CYL:MIX
\u3000\u3000 S C A
\u3000\u3000-7.50 -0.50 96
\u3000\u3000S.E. -7.75

\u3000\u3000 S C A
\u3000\u3000-8.00
\u3000\u3000S.E. -8.00

\u3000\u3000PD:54


\u3000\u3000REF.DATA---\u662freference data\u7684\u7f29\u79f0\uff0c\u610f\u601d\u662f\u53c2\u7167\u7684\u6570\u636e\u3002
\u3000\u3000\uff08\u7535\u8111\u81ea\u52a8\u9a8c\u5149\u7ed9\u51fa\u7684\u53c2\u7167\u6570\u636e\uff09
\u3000\u3000VD:12.0 \u6307\u955c\u773c\u8ddd \u3002
\u3000\u3000CYL:MIX \u6307\u6df7\u5408\u6563\u5149\u3002
\u3000\u3000---\u662f\u201c\u53f3\u201d\u7684\u610f\u601d\u3002right\u7684\u7f29\u5199\u3002\u8fd9\u91cc\u6307\u53f3\u773c\u3002
\u3000\u3000---\u662f\u201c\u5de6\u201d\u7684\u610f\u601d\u3002left\u7684\u7f29\u5199\u3002\u8fd9\u91cc\u6307\u5de6\u773c\u3002
\u3000\u3000S----\u7403\u955c\u3002
\u3000\u3000C----\u67f1\u955c\u3002
\u3000\u3000A----\u67f1\u955c\u7684\u8f74\u4f4d\u3002\uff08\u5373\u6563\u5149\u7684\u8f74\u4f4d\uff09
\u3000\u3000S.E.---\u6307\u5e73\u5747\u503c\u3002
\u3000\u3000PD---\u6307\u77b3\u8ddd\u3002 \u4f60\u662f54mm\u3002\uff08\u53cc\u773c\u77b3\u5b54\u4e2d\u5fc3\u7684\u8ddd\u79bb\uff09

\u3000\u3000\u4f60\u7684\u7535\u8111\u9a8c\u5149\u7ed3\u679c\u662f\uff1a
\u3000\u3000\u53f3\u773c\uff1a750\u5ea6\u8fd1\u89c6\u5e2650\u5ea6\u6563\u5149\u8f74\u4f4d\u572896.
\u3000\u3000\u5de6\u773c\uff1a800\u5ea6\u8fd1\u89c6\u3002

\u3000\u3000\u8fd9\u53ea\u662f\u7535\u8111\u7ed9\u51fa\u7684\u53c2\u8003\u6570\u503c\uff0c\u4f60\u771f\u6b63\u9700\u8981\u7684\u5ea6\u6570\u8fd8\u9700\u8981\u7efc\u5408\u9a8c\u5149\u540e\u5f97\u51fa\u3002

\u3000\u3000---------------------------------------------------------------

\u3000\u3000KRT.DATA

\u3000\u3000 D MM A
\u3000\u3000R1 45.00 7.51 129
\u3000\u3000R2 45.75 7.38 39
\u3000\u3000AVE 45.25 7.45

\u3000\u3000CLY: -0.75 129

\u3000\u3000 D MM A
\u3000\u3000R1 45.25 7.47 24
\u3000\u3000R2 45.75 7.37 114
\u3000\u3000AVE 45.50 7.42

\u3000\u3000CYL: -0.50 24


\u3000\u3000KRT.DATA\u6307\u7684\u662f--\uff08keratometer \u89d2\u819c\u66f2\u7387\u8ba1\u6d4b\u51fa\u7684\u6570\u636e\uff09
\u3000\u3000D---\u5c48\u5149\u5ea6\u3002
\u3000\u3000MM---\u6beb\u7c73\uff08\u66f2\u7387\u534a\u5f84\uff09\u3002
\u3000\u3000A---\u8f74\u4f4d\u3002
\u3000\u3000R1\u3001R2--\u5206\u522b\u6307\u4e24\u7ec4\u6570\u636e\u3002
\u3000\u3000AVE---\u5e73\u5747\u503c\u3002
\u3000\u3000CYL---\u6563\u5149\u3002

\u3000\u3000\u4ee5\u4e0a\u7ed3\u679c\u4e3a\uff1a
\u3000\u3000\u53f3\u773c\u89d2\u819c\u7684\u66f2\u7387\u4e3a\uff1a\u5e73\u5747\u503c\uff1a45.25\u5c48\u5149\u5ea6\u3001\u66f2\u7387\u534a\u5f84\u4e3a7.45mm\u3002
\u3000\u3000\u6563\u5149\u4e3a\uff1a-0.75\u5c48\u5149\u5ea6\uff0c\u8f74\u4f4d\u5728129.
\u3000\u3000\u5de6\u773c\u89d2\u819c\u7684\u66f2\u7387\u4e3a\uff1a\u5e73\u5747\u503c\uff1a45.50\u5c48\u5149\u5ea6\u3001\u66f2\u7387\u534a\u5f84\u4e3a7.42mm\u3002
\u3000\u3000\u6563\u5149\u4e3a\uff1a-0.50\u5c48\u5149\u5ea6\uff0c\u8f74\u4f4d\u572824.

\u3000\u3000-------------------------------------------------------------------

\u3000\u3000\u3010\u89d2\u819c\u66f2\u7387\u8ba1\u3011\u662f\u7528\u6765\u6d4b\u91cf\u89d2\u819c\u8868\u9762\u7684\u5f27\u5ea6\u548c\u5c48\u5149\u5ea6\uff0c\u4ee5\u53ca\u89d2\u819c\u6563\u5149\u7684\u8f74\u5411\u548c\u6563\u5149\u5ea6\u6570\u7684\u4e00\u4e2a\u5de5\u5177\u3002

\u3000\u3000\u90a3\u4e48\u54b1\u4eec\u5148\u6765\u7406\u89e3\u4e00\u4e0b\uff1a

\u3000\u3000\u89d2\u819c\u66f2\u7387\u662f\u4ec0\u4e48\uff1f

\u3000\u3000\u66f2\u7387\u662f\u4ec0\u4e48\uff1f\u662f\u8868\u793a\u66f2\u7ebf\u5f2f\u66f2\u7a0b\u5ea6\u7684\u91cf\u3002

\u3000\u3000\u89d2\u819c\u662f\u7531\u65e0\u6570\u4e2a\u5706\u5f27\u66f2\u7ebf\u6784\u6210\u7684\u3002

\u3000\u3000\u5706\u5f27\u7684\u66f2\u7387\u534a\u5f84\uff0c\u5c31\u662f\u4ee5\u8fd9\u6bb5\u5706\u5f27\u4e3a\u4e00\u4e2a\u5706\u7684\u4e00\u90e8\u5206\u65f6\uff0c\u6240\u6210\u7684\u5706\u7684\u534a\u5f84\u3002

\u3000\u3000\u66f2\u7387\u534a\u5f84\u7684\u5012\u6570\u5c31\u662f\u66f2\u7387\u3002\u66f2\u7387 k = (\u8f6c\u8fc7\u7684\u89d2\u5ea6/\u5bf9\u5e94\u7684\u5f27\u957f\uff09\u3002

\u3000\u3000\u89d2\u819c\u5b58\u5728\u5185\u8868\u9762\u548c\u5916\u8868\u9762\u4e24\u4e2a\u9762\u3002\u6240\u4ee5\uff0c\u5b9e\u9645\u66f2\u7387\u4e3a\u5185\u5916\u7684\u4ee3\u6570\u548c\u3002

\u3000\u3000\u6b63\u5e38\u89d2\u819c\u66f2\u7387\u4e3a\uff1a
\u3000\u3000\u66f2\u7387\u534a\u5f84\uff1a \u524d\u8868\u97627.8mm,\u540e\u8868\u97626.8mm \u3002
\u3000\u3000\u5c48\u5149\u529b\uff1a \u524d\u9762+48.83D,\u540e\u9762-5.88D\uff0c \u603b\u5c48\u5149\u529b +43D \u3002
\u3000\u3000\u4ee5\u4e0a\u7684\u89d2\u819c\u66f2\u7387\u662f\u901a\u8fc7\u4e34\u5e8a\u5927\u6837\u672c\u8d44\u6599\u5f97\u51fa\u7684\u5e73\u5747\u503c\u3002\u9ad8\u4e00\u4e9b\u6216\u4f4e\u4e00\u4e9b\u90fd\u662f\u6b63\u5e38\u7684\uff0c\u4f60\u7684\u503c\u6ca1\u6709\u95ee\u9898\u3002\u653e\u5fc3\u5427\uff01
\u3000\u3000\u5bf9\u4e8e\u5927\u4e8e47D\uff0c\u8981\u9ad8\u5ea6\u6000\u7591\u6709\u5706\u9525\u89d2\u819c\u7684\u53ef\u80fd\u3002\u89d2\u819c\u5730\u5f62\u56fe\u53ef\u4ee5\u76f4\u89c2\u7684\u770b\u51fa\u3002

\u3000\u3000--------------------------------------------------------------------

\u3000\u3000\u773c\u533b---\u674e\u4f1f

\u3000\u3000\uff08\u6709\u773c\u75c5\u95ee\u9898\uff0c\u53ef\u76f4\u63a5\u5230\u6211\u7684\u535a\u5ba2\u4e2d\u7559\u8a00\uff09

看上去像是电脑验光的结果
如你所述:
(右眼) SPH(球镜) CYL(柱镜) AX(轴位)
-12.25 +0.5 90
(左眼) SPH(球镜) CYL(柱镜) AX(轴位)
-11.25 0.00 180
PD(瞳距):61(mm)
右眼近视 -12.25D联合散光+0.5D轴位90度
左眼近视 -11.25D 没有散光.
瞳距顾名思义就是两眼瞳孔中心距离了,没有正常不正常的.也没有一个固定的范围,以我近几年的工作中观察,大概为55-66之间,这个没什么问题,也不会引发什么,每个人情况不同,瞳距自然不同就好象身材一样有的胖一点有的瘦一点.(你的是比较普遍的.我接触的59-62是最多的.)
另外AX指的是散光的轴位,也就是它的屈光度是作用在哪个方向上的(屈光度最强的方向与所标示轴位垂直.)
左眼的CYL是0,没有散光.轴位自然就不用去管它.
你的眼球在关于PD和AX方面没什么问题,但是不知道用这个度数你的视力能达到什么样的程度,你给的这个度数已经很大了.
希望你的矫正视力能高一点~~~

扩展阅读:视力pd正常值对照表 ... 视力ax正常值是多少 ... 怀孕sd值正常值参照表 ... ref data正常参考范围 ... 眼科pd正常范围 ... 视力检查pd多少正常 ... #ref怎样恢复数据 ... ref data 正常值参照表 ... 怀孕29周sd值对照表 ...

本站交流只代表网友个人观点,与本站立场无关
欢迎反馈与建议,请联系电邮
2024© 车视网