15KW电机,700米远,用多大电缆 功率15千瓦的电机,距离600米,用多大的电缆?

15KW\u7535\u673a\uff0c700\u7c73\u8fdc\uff0c\u7528\u591a\u5927\u7535\u7f06

\u4e09\u76f8380V15KW\u7535\u673a\u75286\u5e73\u65b9\u7684\u94dc\u7535\u7f06\u5c31\u884c\uff0c\u4f46700\u7c73\u7684\u4f9b\u7535\u8ddd\u79bb\u592a\u8fdc\uff0c\u5e94\u91c7\u53d6\u63d0\u9ad8\u4f9b\u7535\u7535\u538b\u7684\u63aa\u65bd\u3002

R=\u03c1L/s\u630910\u5e73\u65b9\u6beb\u7c73\u7b97\u4e3a600\uff0a0.0172/10=1.32\u6b27\uff0c\u598215\u74e6\u7535\u673a\uff0c\u7535\u6d41\u7ea630A\uff0c\u90a3\u4e48\u538b\u964d\u4e3a30\uff0a1.32=30.96v\uff0c\u7535\u538b\u635f\u5931\u7ea631v\uff0c\u6309\u542f\u52a8\u65f6\u7b97\uff0c\u7535\u6d41\u8fdc\u8d8530A\uff0c\u7535\u538b\u635f\u5931\u66f4\u5927\uff0c\u6050\u6015\u8d77\u52a8\u56f0\u96be\u4e86\u3002\u6240\u4ee5\u8981\u770b\u4f60\u7684\u76f8\u7535\u538b\u9ad8\u4f4e\u51b3\u5b9a\uff0c\u5982\u679c\u9ad8\uff08\u8fd1400v\uff09\uff0c10\u5e73\u65b9\u94dc\u7ebf\u53ef\u4ee5\u51d1\u5408\uff0c\u5982\u679c\u4f4e\uff0c\u90a3\u5c31\u4e0d\u884c\u4e86\uff0c\u8fd8\u662f16\u5e73\u65b9\u94dc\u7ebf\u6709\u4fdd\u969c\u3002

由于距离较远,主要考虑线路的压降。
第一步,计算电流:15KW电机 电流I=P/1.732UcosΦ=15/1.732X0.38X0.8=28A
第二步,设定允许最低压降为25V,计算线路允许的最大电阻: R=25/28=0.9欧
第三步,导线截面积S=pL/R=0.017X700/0.9=13.2(平方毫米)
选用16平方毫米的铜电缆可以安全正常使用。

如果用铝电缆:导线截面积S=pL/R=0.029X700/0.9=22.5(平方毫米)
选用25平方毫米的铝电缆可以安全正常使用。

5KW的电机,如果距离只有几十米,只需要6平方毫米的铜线,两三百米,
只需要10平方毫米的铜线,距离越长,截面积要得越大。

700米远的距离,放电缆时主要考虑的就不是电缆安全载流量问题了,而是主要考虑压降问题了!

15KW电机额定电流约为I=30A,铜线常温导电率约为 ρ=0.0173欧姆平方毫米/米,根据公式R=ρ×L/S 和ΔU=R×I,可计算得出压降。

四芯10个平方铜线压降约为36V ;16平方铜线约为22V ;25个平方的铜线约为14V。
这就要看你电机最大压降为多少了。这几种线的载流量拖30KW电机完全没问题,关键就看你压降怎样要求。

根据电工手册 压降小于7%,则380V×7%=26V,则根据此应选取16平方铜线!

三相380V供电
电流I可按30A估算,线路距离L=700(m),压降ΔU<7%。

铜芯截面积 Scu=L×I÷352=700×30÷352=60mm2,
明敷可选BV70 mm2,或 VV70 mm2。

铝芯截面积 Sal=L×I÷217=700×30÷217=96mm2 。
明敷可选BLV95 mm2

(公式与数据引自《输配电速查速算手册》,P.129~142)

  • 15kw鐢垫満鐢鍑犲钩鏂圭嚎
    绛旓細鍐浣跨敤15鍗冪摝鐢靛櫒鎴栬呮槸鐢垫満鐨勬椂鍊欙紝涓瀹氳娉ㄦ剰瀹夊叏鐢垫祦鐨勯棶棰橈紝濡傛灉璇磋秴杩囦簡瀹夊叏鐢垫祦锛岄偅涔堢嚎璺細鍙戠儹锛屼篃灏辨槸璇存湁寰堝ぇ鐨勫嚑鐜囦細鍑虹幇鐏伨鐨勬儏鍐点備笁銆15鍗冪摝鐨勭數鍣ㄨ璐拱澶氬ぇ鐨勭‖绾 杩欒鐪嬫妸15鍗冪摝鐨勭數鍣ㄦ斁鍦ㄥ澶х殑鐢靛帇褰撲腑浣跨敤锛濡傛灉鏄斁鍦ㄥ崟鐩哥數璺綋涓娇鐢紝閭d箞闇瑕佽喘涔2×10骞虫柟姣背鐨勭‖绾匡紝瑕...
  • 15鍗冪摝鐨380浼鐢垫満,璇ョ敤澶氬ぇ骞虫柟鐨勯摐瀵肩嚎
    绛旓細15kw鐢靛姩鏈鐢垫祦璁$畻锛歅=鈭3脳U脳I脳cos鈭甀 =P梅锛堚垰3脳U脳cos鈭級=15梅锛堚垰3脳0.38脳0.85锛=27锛圓锛夋牴鎹數娴佸鐓ц〃锛15KW鐢垫満鑷冲皯瑕侀夋嫨6骞虫柟鐨勯摐鑺數绾裤6骞虫柟鐨勯摐鑺數绾挎槑绾挎暦璁惧畨鍏ㄦ埅娴侀噺绾50A銆傚弬鑰冪數绾挎埅娴侀噺瀵圭収琛細
  • 15kw鐨勭數鏈虹敤澶氬ぇ鐨勭嚎,鏈変粈涔堝叕寮忕殑銆
    绛旓細濡傛灉P=15kw鐨涓夌浉寮傛鐢垫満锛Y鍨嬫帴绾匡紝380V棰濆畾鐢靛帇锛屽姛鐜囧洜鏁0.87锛屾晥鐜0.9锛屽垯棰濆畾鐢垫祦 I1=P/(0.87*0.9)/380/3=16.8A 鑰冭檻1.2鍊嶇殑瑁曢噺锛孖=1.2*I1=20.16A 绗簩姝ワ細鏍规嵁鐢垫祦鍜岀嚎寰勫叧绯伙紝閫夋嫨绾跨殑澶у皬锛涚數娴佸ぇ灏忎笌绾垮緞鏈夊緢璇︾粏鐨勫叧绯伙紝浣犲彲鏌ョ浉鍏宠祫鏂欐垨鐧惧害锛屽湪姝や笉澶氳禈杩般20A宸﹀彸...
  • 15kw鐢垫満鐢澶氬ぇ鐨勯摑绾?
    绛旓細鏈嬪弸锛岃繖杩滆繙瓒呰繃姝e父渚涚數璺濈浜嗐備竴鑸槸涓嶈秴杩500绫崇殑渚涚數鍗婂緞鐨勩備綘蹇呴』渚涚數1km锛岄偅涔堜笉鑳藉皯浜10骞虫柟宸﹀彸鐨勯摑鑺嚎鎵嶅彲浠ョ殑锛岀粏浜鐢靛姩鏈鍚姩寰堝洶闅剧殑銆
  • 15KW鐨勭數鍔ㄦ満,绂荤數婧愭湁100绫宠闂鐢ㄥ澶х殑鐢电紗,鍏蜂綋鎬庝箞绠?
    绛旓細380浼忎笁鐩镐氦娴佺數400绫宠寖鍥翠箣鍐锛15鍗冪摝鐨勭數鍔ㄦ満鐢垫祦澶х害30a銆備綘鍙互鏍规嵁瑕佹眰閫夋嫨涓嶅悓鐨勭數缂嗐
  • 涓鍙380V15KW鐢垫満,渚涚數璺濈1200绫,鑰冭檻绾胯矾鍘嬮檷,闇瑕鐢ㄥ绮楃殑閾滆姱鐢电紗...
    绛旓細浣犵敤25骞虫柟鐨勯摐鑺數缂嗭紝鍔犵儹鍣ㄧ殑璐熻嵎瑕侀厤骞筹紝搴旇鏄病闂鐨勶紝濡傛灉 鏂逛究鐨勮瘽鏈濂界敤50骞虫柟鐨勬瘮杈冨ソ銆
  • 浣犲ソ,鎴戞兂璇锋暀涓棶棰,380鐢垫媺400绫冲甫15鍗冪摝鐢垫満宸ヤ綔闇瑕佸绮楃殑鐢电嚎?
    绛旓細380V鐢靛帇400绫冲甫15鍗冪摝鐢垫満锛鍦ㄦ甯告儏鍐典笅鍙互閫夌敤6骞虫柟鐨勯摐绾裤傚洜涓猴紝380V鐢靛帇400V鐨勭數鏈猴紝姝e父鎯呭喌涓嬫槸2A/Kw銆傛墍浠ワ紝15鍗冪摝鐢垫満宸ヤ綔鐨勯瀹氱數娴佸煎湪30A宸﹀彸鍛锛佽岄摐绾跨殑瀹夊叏杞芥祦閲忔槸锛氬鏋滄寜缁忛獙鍙h瘈鏉ヨ绠楃殑璇濓紝灏辨槸10涓5銆備篃灏辨槸璇15 鍗冪摝鐨勭數鏈哄氨鐢6骞虫柟鐨勯摐璐ㄥ绾垮氨琛屽暒锛佽冭檻鍒颁綘鎷夌殑绾垮お闀...
  • 鍗佷簲鍗冪摝鐨鐢垫満绂诲彉鍘嬪櫒鏈杩滆窛绂诲灏戣兘澶熷惎鍔ㄦ庝箞绠楃殑?
    绛旓細涓鑸鐢靛姩鏈璧峰姩鐢靛帇涓嶈兘 浣庝簬棰濅笂瀹氱數鍘85%锛屾甯稿伐浣滅數鍘嬩笉鑳戒綆浜庨 瀹氱數鍘90%銆傜劧鍚庢牴鎹數缂嗘埅闈㈠拰宸ヤ綔鐢垫祦璁$畻绾胯矾鐨勭數鍘嬫崯澶便
  • 500绫崇殑璺濈,15鍗冪摝鐨勭數鍔ㄦ満,380浼忎緵鐢,闂竴涓,鐢鍑犳柟鐨勯摑绾垮仛鐏嚎鍜...
    绛旓細闇瑕35骞虫柟鐨勯摑鑺嚎锛岀數鍘嬫崯澶辩瓑浜嶱.L/50S,鐢靛帇鎹熷け绛変簬鐧惧垎涔嬩簲锛屼篃灏辨槸鐢靛帇闄嶆槸20V
  • 15KW鐨勭數鏈閰嶅澶х殑绾 瑕佽绠楀叕寮 鍜岃繃绋
    绛旓細鐢垫満鏄15kw鐨瑕佺敤6骞虫柟鐨勯摐鐢电紗鍜50A寮鍏炽傚厛纭畾鏉′欢锛岀數鍘嬩负380V锛屽姛鐜囧洜鏁0.85锛屼笁鐩镐緵鐢碉紝渚涚數璺濈杈冪煭锛堝拷鐣ュ帇闄嶉棶棰橈級銆傛牴鎹姛鐜囧叕寮廝=1.732UIcos蠁鏈 I=P/(1.732Ucos蠁)=15/(1.732x0.38x0.85)=27A(鎸変笁鐩稿競鐢佃绠楋紝鍔熺巼鍥犳暟鍙0.85)閫夋嫨閾滆姱瀵肩嚎锛屾煡琛ㄥ緱锛4骞虫柟姣背鐨勫绾胯浇娴侀噺...