住宅顶层消防排烟风机安装不规范 消防排烟风机能否安装在住宅屋顶

\u4f4f\u5b85\u9876\u5c42\u6d88\u9632\u6392\u70df\u98ce\u673a\u5b89\u88c5\u4e0d\u89c4\u8303

\u6d88\u9632\u6392\u70df\u98ce\u673a\uff0c\u5e73\u65f6\u662f\u4e0d\u5f00\u542f\u7684\uff0c\u58f0\u97f3\u518d\u5927\u4e5f\u4e48\u6709\u95ee\u9898\u7684\u3002\u4e07\u4e00\u98ce\u673a\u542f\u52a8\u4e86\uff0c\u4f60\u5f71\u54cd\u5230\u4f60\u4f11\u606f\uff0c\u4f60\u5c31\u5e94\u8be5\u9a6c\u4e0a\u53bb\u9003\u547d\u4e86\u3002\u88c5\u5728\u5929\u9762\u662f\u7b26\u5408\u89c4\u5b9a\u3002

\u5475\u5475\uff0c\u901a\u5e38\u9ad8\u5c42\u90fd\u662f\u88c5\u5728\u5c4b\u9876\u7684\uff0c\u4e0d\u4f1a\u5f71\u54cd\u4f60\u4f11\u606f\u7684
\u4e3a\u4ec0\u4e48\u4e0d\u4f1a\u5f71\u54cd\u4f60\u4f11\u606f\u5462\uff0c\u662f\u56e0\u4e3a\u5b83\u4e00\u822c\u90fd\u4e0d\u4f1a\u4f7f\u7528\u7684\uff0c\u5c31\u662f\u4e0d\u4f1a\u542f\u52a8\u7684\uff0c
\u4e0d\u542f\u52a8\u5c31\u5bf9\u4f60\u6ca1\u6709\u4efb\u4f55\u5f71\u54cd\u7684\uff0c
\u4e0d\u8fc7\uff0c\u563f\u563f\uff0c\u5b83\u4e00\u65e6\u5f71\u54cd\u4f60\uff0c\u5c31\u662f\u8bf4\u4e00\u65e6\u542f\u52a8\uff0c\u563f\u563f\uff0c\u4f60\u5c31\u81ea\u6c42\u591a\u798f\u5427\uff0c\u5c31\u4e0d\u662f\u5f71\u4e0d\u5f71\u54cd\u4f60\u7684\u4e8b\u4e86\uff0c\u800c\u662f\u706b\u707e\u53d1\u751f\u4e86\uff0c\u4f60\u8fd8\u80fd\u4e0d\u80fd\u575a\u6301\u5230\u4ee5\u540e\u88ab\u5b83\u5f71\u54cd\u7684\u4e8b\u4e86~~~~

消防排烟通风机运行的震动限值应符合JB/T8689的有关规定,
消防排烟通风机必须是工程所在地消防部门认可的设备.
设置于建筑物的机械排烟系统内,当建筑物发生火灾时,用以排除烟气的通风
(该设备平时亦可用于通风换气)
通风机随机文件有: a) 产品合格证; b) 产品说明书或样本; c) 装箱单(成套供应明细表); d) 消防排烟通风机备案登记证书影印照片。

建筑商安装消防排烟风机确实符合消防设备的安装要求,噪音问题应与物业开发商及当地消防部门协商. 新闻有报道过高层消防排烟机噪音扰民,最后就是协商.如果他们相关备案证明齐全的话,也只能协商了.买顶楼确实好多隐患问题存在. 希望早日解决.舒心才最重要.

如果与建筑安装设计图纸无异,那么应该就是规范的了,因为设计图纸是经过消防行政机关审核批准并验收过的!

风机安装在楼顶,行不行,规范上并没有涉及,当房屋设计时,对载荷、减振、噪音都有设计,施工也是按国家规范完成,那就可行。风机一定是装在一个减振架上,工作时人站在机座旁没有振感,现场噪音小于70分贝,(小于菜场的声音)。没有达到这些就不行。

消防救火用不存噪音问题,除了调试平时是不开的,防火工作,人人有责.
若平时作为排烟排风用风机应当考虑,噪声问题.

  • 楂樺眰寤虹瓚闃茬儫鎺掔儫绯荤粺鐨勯獙鏀跺拰缁存姢绠$悊?
    绛旓細鈶℃鏌ヨ绯荤粺椋庢満鑱斿姩鎶曚汉杩愯鎯呭喌銆傚強娑堥槻鎺у埗瀹ゅ唴瀵规湁鍏鎺掔儫闃銆侀侀鍙e拰椋庢満鍔ㄤ綔鐨勫弽棣堜俊鍙枫傗憿鍦ㄧ浉鍏虫ゼ灞傛煡鐪嬮侀鍙e強鎺掔儫闃鏄惁鎸夎璁¤姹傚紑鍚傗懀鍦ㄥ墠瀹ゅ唴鐢ㄩ閫熶华娴嬭瘯椋庡彛鍙婃帓鐑熼榾鐨勫钩鍧囬閫燂紝鏍哥畻閫侀鏈哄強鎺掔儫鏈虹殑瀹為檯椋庨噺銆傛鏁板间竴鑸瘮椋庢満鐨勯瀹氶閲忓皬銆備絾涓嶅簲灏忎簬10%;15%銆傚璧伴亾鍐呭崟鐙殑鎺掔儫...
  • 闃鎺掔儫鍜岄氶绌鸿皟绛夋潯娆剧殑涓浜涘缓璁?
    绛旓細鍚屾牱瀵逛笓鐢ㄨ酱娴佸紡鎺掔儫椋庢満鏄惁涓瀹氳璁惧湪鏈烘埧鍐,灏ゅ叾鏄綋鍦颁笅瀹ゅ崟涓埧闂撮潰绉皬浜50m2 鐨勮澶囩敤鎴垮唴璁句笉甯﹂绠$殑涓撶敤杞存祦寮忕儫椋庢満鏃,绗旇呰涓哄彲涓嶈涓撶敤鏈烘埧銆傘婇珮瑙勩嬬5. 2. 7 鏉℃潯鏂囪鏄庘滄湰娆″眬閮ㄤ慨瀹氭椂,鑰冭檻鍒伴氶銆佺┖璋冩満鎴挎槸閫氶銆佹帓鐑熺姹囬泦鐨勬埧闂,涔熸槸鐏娍钄撳欢鐨勯噸瑕侀儴浣,涓洪樆姝㈤氶銆佺┖璋冩満鎴垮唴澶...
  • 娑堥槻鎺掔儫椋庢満瑙勮寖娑堥槻鎺掔儫椋庢満鐗圭偣
    绛旓細鎺ヤ笅鏉ュ皬缂栦负澶у浠嬬粛娑堥槻鎺掔儫椋庢満瑙勮寖鍙婃秷闃叉帓鐑熼鏈虹壒鐐广傛秷闃叉帓鐑熼鏈鸿鑼1銆佹秷闃叉帓鐑熼鏈哄湪瀹夎鍓嶄竴瀹氳鍋氬埌瀵瑰叾杩涜鍏呭垎鐨勪簡瑙o紝骞惰鐪熶粩缁嗙殑瀵规秷闃叉帓鐑熼鏈鸿繘琛屽叏闈㈡鏌ワ紝纭繚椋庢満鐨勫畬濂藉拰闄勪欢鐨勯綈鍏ㄥ畬鏁淬2銆佹秷闃叉帓鐑熼鏈虹殑杩涘嚭鍙g殑椋庣蹇呴』鏈夊叾鐙珛鐨勬敮鎾戯紝绠¢亾鐨勯噸閲忎笉鑳芥柦鍔犲湪椋庢満鐨勯儴浠朵笂銆傝屼笖椋庢満...
  • 濡備綍瀹夎娑堥槻鎺掔儫椋庢満
    绛旓細瀹夎鍚庣數鏈轰笉鍙湁鍊炬枩鐜拌薄锛2銆瀹夎椋庢満鏃跺簲浣跨數鏈虹殑璋冭妭铻烘爴澶勪簬鏂逛究鎿嶄綔鐨勪綅缃紝浠ユ柟渚夸娇鐢ㄦ椂璋冭妭鐨甫鏉剧揣锛3銆佸畨瑁娑堥槻鎺掔儫椋庢満鏀灦鏃讹紝涓瀹氳璁╂敮鏋朵笌鍦板熀骞抽潰姘村钩绋冲浐锛屽繀瑕佹椂鍦ㄩ鏈烘梺瀹夎瑙掗搧杩涜鍐嶅姞鍥猴紱4銆椋庢満瀹夎瀹屽悗锛岃瀵瑰叾鍛ㄥ洿瀵嗗皝鎬ц繘琛屾鏌ャ傚鏈夌┖闅欙紝鍙敤闃冲厜鏉挎垨鑰呯幓鐠冭兌杩涜瀵嗗皝銆
  • 娑堥槻鎺掔儫椋庢満鍙互鐢ㄧ數鐏紑鍏冲悧?
    绛旓細涓嶇鍚堢殑锛鎺掔儫椋庢満鍦ㄥ眿椤讹紝浣嗘槸椋庢満鎺у埗绠变笉涓瀹氬湪灞嬮《锛屽彟澶娑堥槻鎺у埗瀹ゅ绾跨洏鏈夌洿鎺ュ惎鍔ㄥ仠姝㈡寜閽紝鐜板満濡傛灉闇瑕佽缃殑閭e氨鏄缃寜閽銆傜収鏄庡紑鍏虫槸涓嶈鐨勩
  • 鏂瑙勮寖灞嬮《寮娑堥槻鎺掔儫椋庢満鏄惁杩樿兘鐢
    绛旓細鏂瑙勮寖灞嬮《寮娑堥槻鎺掔儫椋庢満杩樿兘鐢ㄣ傛牴鎹煡璇㈢浉鍏宠祫鏂欎俊鎭紝鎺掔儫椋庢満鏄竴绉嶅彲浠ュ皢鍘ㄦ埧涓姞宸ラ鐗╄繃绋嬩腑浜х敓鐨勫紓鍛炽侀珮娓┿佹补鐑熸皵浣撹繀閫熸帓璧扮殑鏈烘锛岃鏈哄櫒鐗圭偣鏄愰珮娓╂ц兘鑹ソ銆佹晥鐜囬珮銆傞鏈虹殑绫诲瀷鏈夌蹇冮鏈恒佽酱娴侀鏈恒佺蹇冮鏈恒佽酱娴侀锛屾牴鎹┖闂村ぇ灏忓拰鎺掔儫缃╃殑甯冪疆鎯呭喌閫夋嫨閫傚悎灏忓ぇ鐨勬満鍣ㄣ
  • 娑堥槻鎺掔儫椋庢満瑙勮寖娑堥槻鎺掔儫椋庢満鐗圭偣
    绛旓細瑙勮寖锛1. 鍦瀹夎娑堥槻鎺掔儫椋庢満涔嬪墠锛屽繀椤诲鍏惰繘琛岃缁嗕簡瑙o紝骞惰繘琛屽叏闈㈢殑妫鏌ワ紝浠ョ‘淇濋鏈虹殑姝e父杩愪綔鍜岄檮浠剁殑瀹屾暣鎬с2. 娑堥槻鎺掔儫椋庢満鐨勮繘鍑哄彛椋庣蹇呴』鏈夌嫭绔嬬殑鏀拺锛屼笖绠¢亾閲嶉噺涓嶅緱浣滅敤浜庨鏈虹殑閮ㄤ欢涓娿傞鏈虹殑杩炴帴鏂瑰紡搴旇鏄嚜鐒惰繛鎺ワ紝閬垮厤寮鸿杩炴帴銆3. 椋庢満鐨勬帴绾垮繀椤绘纭紝鎺ュ湴蹇呴』鑹ソ锛屼笖蹇呴』鏈夌嫭绔嬬殑...
  • 娑堥槻娉曡閲屾湁娌℃湁瑙勫畾璁捐鎺掔儫椋庢満瑕佸涔呮妸娴撶儫鎶借蛋
    绛旓細鍦ㄣ奊B50016-2006寤虹瓚璁捐闃茬伀瑙勮寖銆嬫湁瑙勮寖瑕佹眰銆
  • 涓鏍嬮珮灞傚缓绛,娑堥槻椋庢満涓鎺掔儫椋庢満涓庢鍘嬮侀鏈洪兘蹇呴』瀹夎?杩樻槸瀹夎涓涓...
    绛旓細娑堥槻姝e帇閫侀鏄湪鍙戠敓鐏伨鏃朵负浣垮洶鍦ㄦゼ鍐呯殑浜哄憳鍙婃晳鎻翠汉鍛樿緭閫佹柊椴滅┖姘旂殑锛佽鎺掔儫鏄敤鏉ユ娊鍑鸿捣鐏椂鐨勭儫闆剧殑锛佷綘璁や负涓や釜閭d釜閲嶈锛
  • 娑堥槻鎺掔儫椋庨亾鐨瀹夎璁剧疆瑕佹眰鏈夊摢浜?
    绛旓細寤虹瓚宸ョ▼娑堥槻璁炬柦鏂藉伐鍙婇獙鏀瑙勮寖锛堥槻鎺掔儫绯荤粺绡囷級1.1 璁惧鍙婇厤浠惰繘鍦 1.1.1 涓鑸瀹 1銆 涓昏璁惧搴旀湁瑁呯娓呭崟銆佽澶囪鏄庝功銆佷骇鍝佽川閲忓悎鏍艰瘉涔﹀拰浜у搧鎬ц兘妫娴嬫姤鍛婄瓑闅忔満鏂囦欢锛岃繘鍙h澶囪繕搴斿叿鏈夊晢妫鍚堟牸鐨勮瘉鏄庢枃浠躲傛墍鏈変骇鍝佺殑鍨嬪彿銆佽鏍煎潎搴旂鍚堣璁¤姹傘2銆 璁惧瀹夎鍓嶏紝搴旇繘琛屽紑绠辨鏌ワ紝骞跺舰鎴愰獙鏀...