配电房防雷接地怎么做 配电房的接地怎么做

\u914d\u7535\u623f\u9632\u96f7\u63a5\u5730\u600e\u4e48\u505a

\u914d\u7535\u623f\u9632\u96f7\u63a5\u5730\u5176\u5b9e\u662f\u6709\u4e25\u683c\u8981\u6c42\u548c\u89c4\u8303\u8bbe\u8ba1\u7684\uff0c\u5728\u8fd9\u91cc\u53ea\u80fd\u5927\u6982\u8bf4\u8bf4\uff0c\u4ec5\u4f9b\u53c2\u8003\uff0c\u4e0d\u80fd\u4f5c\u4e3a\u65bd\u5de5\u4f9d\u636e\u3002
\u4e00\u822c\u5728\u914d\u7535\u623f\u571f\u5efa\u65bd\u5de5\u4e4b\u524d\u5c31\u8981\u57cb\u8bbe\u63a5\u5730\u7f51\uff0c\u9996\u5148\uff0c\u95f4\u96945\u7c73\u5de6\u53f3\u6253\u63a5\u5730\u6869\uff08\u76f4\u5f8410\u516c\u5206\u4ee5\u4e0a\u9540\u950c\u94a2\u7ba1\uff0c\u5782\u76f4\u6253\u5165\u5730\u4e0b2.5\u7c73\u4ee5\u4e0a\uff09\uff0c\u7136\u540e\u75285\u516c\u5206\u9540\u950c\u6241\u94a2\u5c06\u63a5\u5730\u6869\u710a\u63a5\u6210\u7f51\u72b6\u7ed3\u6784\uff0c\u6cbf\u7740\u914d\u7535\u623f\u5916\u56f4\u5e03\u8bbe\u4e00\u5708\u3002\u710a\u63a5\u8981\u642d\u710a\uff0c\u4e0d\u80fd\u5bf9\u710a\u3002\u63a5\u5730\u7f51\u4f4d\u4e8e\u5730\u9762\u4ee5\u4e0b50\u516c\u5206\u3002\u5efa\u7b51\u7269\u7684\u94a2\u7b4b\u5b89\u88c5\u89c4\u8303\u548c\u63a5\u5730\u7f51\u710a\u63a5\u3002\u914d\u7535\u623f\u5185\u90e8\u8bbe\u5907\u7684\u63a5\u5730\u7ebf\u4e5f\u548c\u63a5\u5730\u7f51\u710a\u63a5\u7262\u56fa\u3002\u63a5\u5730\u7f51\u63a5\u5730\u7535\u963b\u5e94\u8be5\u5c0f\u4e8e\u89c4\u5b9a\uff08\u597d\u50cf\u662f2\u6b27\u59c6\uff09\u3002\u5927\u6982\u5c31\u8fd9\u6837\u3002

1 \u5728\u914d\u7535\u623f\u5468\u56f4\u7684\u5730\u4e0b\u94fa\u8bbe\u63a5\u5730\u7f51\u548c\u63a5\u5730\u6781\uff0c\u4f7f\u5f97\u63a5\u5730\u7f51\u7684\u63a5\u5730\u7535\u963b\u8fbe\u5230\u8bbe\u8ba1\u503c\uff1b
2 \u7528\u4e24\u6839\u4ee5\u4e0a\u7684\u6241\u94a2\u5c06\u63a5\u5730\u7f51\u5f15\u5165\u914d\u7535\u623f\u5185\uff1b
3 \u5728\u914d\u7535\u623f\u5185\u8ddd\u5730\u9762100mm\u9ad8\u5ea6\uff0c\u6cbf\u5899\u8bbe\u7f6e\u4e00\u5708\u6241\u94a2\u63a5\u5730\u5e26\uff1b
4 \u6240\u6709\u8981\u6c42\u63a5\u5730\u7684\u7535\u6c14\u8bbe\u5907\uff0c\u90fd\u4ece\u8fd9\u4e2a\u63a5\u5730\u5e26\u4e0a\u7528\u6241\u94a2\u6216\u8005\u5706\u94a2\u5f15\u63a5\u63a5\u5730\u3002

配电房防雷接地其实是有严格要求和规范设计的,在这里只能大概说说,仅供参考,不能作为施工依据。
一般在配电房土建施工之前就要埋设接地网,首先,间隔5米左右打接地桩(直径10公分以上镀锌钢管,垂直打入地下2.5米以上),然后用5公分镀锌扁钢将接地桩焊接成网状结构,沿着配电房外围布设一圈。焊接要搭焊,不能对焊。接地网位于地面以下50公分。建筑物的钢筋安装规范和接地网焊接。配电房内部设备的接地线也和接地网焊接牢固。接地网接地电阻应该小于规定(好像是2欧姆)。大概就这样。

  • 閰嶇數鎴块槻闆锋帴鍦版庝箞鍋
    绛旓細涓鑸湪閰嶇數鎴垮湡寤烘柦宸ヤ箣鍓嶅氨瑕佸煁璁炬帴鍦扮綉锛棣栧厛锛岄棿闅5绫冲乏鍙虫墦鎺ュ湴妗╋紙鐩村緞10鍏垎浠ヤ笂闀閿岄挗绠★紝鍨傜洿鎵撳叆鍦颁笅2.5绫充互涓婏級锛岀劧鍚庣敤5鍏垎闀閿屾墎閽㈠皢鎺ュ湴妗╃剨鎺ユ垚缃戠姸缁撴瀯锛屾部鐫閰嶇數鎴垮鍥村竷璁句竴鍦堛鐒婃帴瑕佹惌鐒婏紝涓嶈兘瀵圭剨銆傛帴鍦扮綉浣嶄簬鍦伴潰浠ヤ笅50鍏垎銆寤虹瓚鐗╃殑閽㈢瓔瀹夎瑙勮寖鍜屾帴鍦扮綉鐒婃帴銆傞厤鐢垫埧鍐呴儴璁惧鐨勬帴鍦...
  • 閰嶇數鎴鍦伴潰瑕鎬庝箞鏂藉伐
    绛旓細棣栧厛浣犲緱璇蜂笓涓氶槻闆锋娴嬫満鏋勬娴嬪嚭閰嶇數鎴挎墍鍦ㄥ缓绛戠墿鐨勫啿鍑绘帴鍦扮數闃锛屽洜涓烘満鎴跨數瀛愯澶囦氦娴佸伐浣滄帴鍦板拰淇濇姢鎺ュ湴鐢甸樆鍊煎簲鈮4.0惟锛屽妫娴嬪嚭鐨勯樆鍊奸珮浜4.0惟灏辫澧炶浜哄伐鎺ュ湴浣撲簡锛屽鏋滄娴嬪嚭鐨勫啿鍑绘帴鍦扮數闃诲煎悎鏍硷紝瀹夎灏辩畝鍗曚簡锛屼綘鍙渶瑕佷粠灞嬪闃查浄妫娴嬪瓟澶勭敤4脳40浠ヤ笂鐨勬墎閽㈢剨鎺ワ紝鐒跺悗鍩嬪湴寮曞叆鏈烘埧鍐咃紝鎵侀挗...
  • 鏌愬伐鍘傚彉閰嶇數鎵闃查浄淇濇姢涓鎺ュ湴瑁呯疆璁捐
    绛旓細1锛灞嬮潰椤舵部鍥涘懆涓鍦堬紝灞嬮潰涓棿鍐嶆潵涓ゆ牴妯殑锛岀闈200锛屼腑闂村啀鏉ヤ竴鏍圭洿鐨勶紝涓庝袱妯氦閿欓儴浣嶈鐒婃帴锛屽啀鍦ㄥ绉拌寮曚袱鎺ュ湴绾垮埌鍦颁笅锛屼笌鎺ュ湴缃戣繛鎺ワ紝浠ヤ笂鍙敤鐩村緞10MM闀閿屽渾閽2锛屽彉鍘嬪櫒瀹わ紝浣庡帇瀹ゅ唴锛屽湪鎵鍦ㄥ湴闈400MM楂樺鐢40*4璐挗鐒婁竴鍦堬紝鎵鏈夊甫鐢佃澶囬兘瑕佷笌鎺ュ湴鍦堢剨鎺ワ紝鍙樺帇鍣ㄥ簳搴ц嚦灏戣鏈変袱涓互涓婃帴鍦...
  • 鐢垫皵宸ョ▼鏂藉伐鏂规硶鎺ュ湴绯荤粺?
    绛旓細1銆佸缓绛戠墿闃查浄锛氬埄鐢ㄥ缓绛戠粨鏋勪富绛嬩綔涓哄紩涓嬬嚎寮曡嚦缁煎悎鎺ュ湴缃戯紝寤虹瓚缁撴瀯涓荤瓔锛4鏍光壆蠁16锛夐渶涓庨洦妫氭敮鎾戞灦鍙潬鑱旀帴銆傛帴鍦颁繚鎶ょ嚎寮曡嚦瀹ゅ唴鍧囧帇鐜紙40脳4闀閿屾墎閽級锛屾墍娑夊強鐨勯噾灞炴瀯浠堕渶鍙潬鎺ュ湴銆傛墍鏈夊煁鍦拌繘鎴风嚎鍏ュ彛澶勶紝灏嗚繘鎴风紗绾跨殑閲戝睘澶栨姢濂楀強杩涙埛鐨勯噾灞炵┛澧欏绠℃帴鍦帮紝鎺ュ湴绾垮紩鑷崇患鍚堟帴鍦颁綋銆2銆佹帴鍦板強...
  • 鎺ュ湴闃查浄宸ョ▼鏂藉伐姝ラ鏈夊摢浜
    绛旓細鈼忛伩闆风嚎寮洸澶勪笉寰楀皬浜90掳锛屽集鏇插崐寰勪笉寰楀皬浜庨晙閿屾墎閾佺洿寰勭殑2.5鍊锛涒棌鍦ㄥ缓绛戠墿鐨勫彉褰㈢紳澶勫簲鍋氶槻闆疯法瓒婂鐞嗐傦紙4锛夌數姘旀帴鍦版柦宸ユ柟娉曪細鐩墠锛屾牴鎹婁綇瀹呰璁¤鑼冦嬶紙GB50096-1999锛夛紝鎺ュ湴鍒朵富瑕侀噰鐢═T銆乀N锛岰锛峉鎴朤N-S鎺ュ湴鏂瑰紡锛屽苟杩涜鎬荤瓑鐢典綅鑱旂粨锛沘.楂/浣庡帇鍙橀厤鐢垫埧璁惧鐨勬帴鍦扮郴缁燂紝鍦ㄦ埧闂村唴鍛ㄥ洿...
  • 閰嶇數鎴挎帴鍦鎵侀搧娌规紗鍒蜂粈涔堥鑹
    绛旓細鎺ュ湴骞茬嚎鍒烽粦鑹叉补婕嗐傛槑鏁风殑鎺ュ湴绾胯〃闈㈡秱浠15~100mm瀹藉害鐩哥瓑鐨勭豢鑹叉紗鍜岄粍鑹叉紗鐩搁棿鐨勬潯绾广傚埛婕嗙殑鏂瑰悜娌℃湁瑕佹眰銆傚湪閰嶇數鍙樺帇鍣ㄤ竴銆佷簩娆′晶瑁呰閬块浄鍣紝骞跺皢閬块浄鍣ㄦ帴鍦板紩涓嬬嚎銆佸彉鍘嬪櫒澶栧3銆佷簩娆′晶涓х偣鍒嗗埆鎺ュ湴銆傚潥鎸佹瘡骞翠竴娆$殑骞村害棰勯槻鎬ц瘯楠岋紝鍙婃椂鏇存崲涓嶅悎鏍肩殑閬块浄鍣紝鍑忓皯鍥犻浄鍑汇佽皭鎸骇鐢熻繃鐢靛帇鎹熷潖...
  • 闃查浄寮曚笅绾,娴嬭瘯鍗″仛娉曡鍥俱
    绛旓細鍒╃敤鏌卞唴閽㈢瓔鍋氬紩涓嬬嚎锛屾垨鎵侀挗鏆楁暦寮曚笅锛屽湪1.6锛1.8 绫冲仛娴嬭瘯鐐癸紝涓嶆柇寮銆備絾娉ㄦ剰鍦ㄦ瘡涓祴璇曠偣鍩嬪湴 涓1 绫冲搴旀湁寮曞嚭澶栧1 绫崇殑鎵侀挗棰勭暀锛屼互澧炴墦鎺ュ湴鏋併傛湁鍦板湀姊佷笌鎵垮彴鏃堕噰鐢ㄣ備竴鑸绉嶆儏鍐电敤浜庡彉閰嶇數鎴涓娿4锛屽彟涓绉嶆殫鏁峰紩涓嬬嚎锛屾槑娴嬭瘯鍗°傚埄鐢ㄦ煴鍐呴挗绛嬪仛寮曚笅绾匡紝鍦ㄧ鍦0.5 绫冲鐒婃帴...
  • 浠涔堟槸鎺ュ湴鎺
    绛旓細鎺ュ湴鎺掍竴鑸槸璇磋鍦ㄨ澶囦笂杩炴帴鎺ュ湴浣撶殑閾滅墝鍜屾部鐫閰嶇數鎴澧欏瑁呯殑闀閿屾墎閾併傚墠鑰呮牴鎹澶囨帴鍦版々瀛斾笌鎺ュ湴浣撶殑鎺ュ湴妗╁瓟瑁呰锛涘悗鑰呬竴鑸部澧欒鍦ㄨ窛绂诲湴闈200锝300mm楂樺害銆傛帴鍦版帓鐨勬帴鍦颁綋鎵嶆湁鍩嬫繁瑕佹眰锛屼竴鑸笉寰楀皯浜0.6绫筹紝鍏蜂綋瑕佹牴鎹幆澧冪瓑鍥犵礌鍐冲畾锛屾渶缁堣浠ユ帴鍦扮數闃绘祴閲忓间负鍑嗭紝涓鑸皬浜4娆у涓哄悎鏍笺傚叿浣...
  • 閬块浄鎺ュ湴缃戞柦宸ュ伐鑹
    绛旓細鍦ㄥ缓绛戠墿鐨勫彉褰㈢紳澶勫簲鍋氶槻闆璺ㄨ秺澶勭悊銆4锛夌數姘鎺ュ湴鏂藉伐鏂规硶 鐩墠锛屾牴鎹婁綇瀹呰璁¤鑼冦嬶紙GB50096-1999锛夛紝鎺ュ湴鍒朵富瑕侀噰鐢═T銆乀N锛岰锛峉鎴朤N-S鎺ュ湴鏂瑰紡锛屽苟杩涜鎬荤瓑鐢典綅鑱旂粨銆俛.楂/浣庡帇鍙閰嶇數鎴璁惧鐨勬帴鍦扮郴缁燂紝鍦ㄦ埧闂村唴鍛ㄥ洿璁剧疆涓鏉¤窛鍦伴潰300mm鐨勬按骞虫帴鍦扮幆鍨嬪甫瑙勬牸搴旀寜鐓ц璁¤姹傘俠.寮鍏虫煖銆侀厤鐢靛睆...
  • 闃查浄鎬庝箞鍋
    绛旓細1銆佺洿鍑婚浄閮ㄥ垎锛氬眿闈㈣鍋氶槻鐩村嚮闆峰伐绋嬶紙涓鑸粰鍦熷缓鍋氫簡锛夛紝寮曚笅绾垮彲浠ュ埄鐢ㄦ煴鍐呬富绛嬶紝鎺ュ湴瑁呯疆鍙互鍒╃敤鍩虹锛岄珮浜庢粴鐞冨崐寰勭殑瑕侀槻渚у嚮闆枫2銆侀浄鐢垫劅搴旈儴鍒嗭細棣栧厛涓嶇浠栨湁鍝簺鐢靛瓙淇℃伅绯荤粺瑕鍋氶槻闆锛岄兘鍙互鍦ㄦ閰嶇數鎴瑁呬竴绾у垎绫诲疄楠岀殑浜у搧娴秾淇濇姢鍣ㄦ垨鑰呴槻闆风锛堝弬鑰冨瀷鍙凤細GBM-120/380锛夛紝鍦ㄦゼ灞傚垎閰嶇數鏌...