负荷约250kW,线路长500米,需用YJV的多大规格电缆,其压降是多少. 200kw500米用多大电缆

\u5173\u4e8e\u7535\u7f06\u538b\u964d\u8ba1\u7b97\u7684\u6c42\u52a9

\u6ee1\u8d1f\u8377250kW\uff0c\u7535\u6d41\u5927\u7ea6500A\uff0cYJV 3*240+1*120\u7535\u7f06\uff0c\u5728\u7a7a\u6c14\u4e2d\u6577\u8bbe\uff0c\u8f7d\u6d41\u91cf\u662f416A\uff0c\u5728\u5730\u4e0b\u76f4\u57cb\u6577\u8bbe399A\uff0c\u663e\u7136\u7535\u7f06\u7684\u89c4\u683c\u662f\u5c0f\u4e86\u3002
\u5982\u679c\u8be5\u7535\u7f06\u5728\u7a7a\u6c14\u4e2d\u6577\u8bbe\uff0c\u65ad\u8def\u5668400A\uff0c\u90a3\u4e48\u8f93\u7535\u6700\u5927\u8d1f\u8377\u5728200kW\u5de6\u53f3\uff08\u6ca1\u8003\u8651\u7535\u538b\u964d\uff09\u3002
\u4f60\u6ca1\u6709\u63d0\u4f9b250KW\u8d1f\u8377\u7684\u8d1f\u8f7d\u6027\u8d28\u3002\u5982\u679c\u6309\u7167\u7535\u7f06400A\u7684\u8f7d\u6d41\u91cf\uff08\u8d1f\u8f7d200kW\uff09\u6765\u8003\u8651\uff0c\u90a3\u4e48\u7ebf\u8def\u7535\u538b\u635f\u5931\uff1a
\u4e09\u76f8\u4ea4\u6d41\u7ebf\u8def\u7684\u7535\u538b\u964d\uff1a\u25b3U=\u221a3\u00d7I\uff08\u7535\u7f06\u7684\u7535\u6d41\uff09\u00d7L\uff08\u7535\u7f06\u7684\u957f\u5ea6\uff09\u00d7{ R\uff08\u7535\u7f06\u5bfc\u4f53\u7684\u6709\u6548\u7535\u963b\uff09\u00d7cos\u03c6+X\uff08\u7535\u7f06\u5bfc\u4f53\u7684\u4ea4\u6d41\u7535\u6297\uff09\u00d7sin\u03c6} \uff0c\u5176\u4e2d\u03c6\u4e3a\u7535\u7f06\u672b\u7aef\u7535\u538b\u4e0e\u7535\u6d41\u4e4b\u95f4\u7684\u76f8\u4f4d\u89d2\u3002
\u7535\u538b\u964d\uff1a\u25b3U=\u221a3\u00d7400\u00d70.615\u00d70.0982\uff0890\u00b0C\uff09\u224842V\uff0c(-42/380)\u00d7100%=-11%\uff0c\u6839\u636e\u56fd\u5bb6\u6807\u51c6GB/12325-2008\u7684\u89c4\u5b9a
5.0.4 \u6b63\u5e38\u8fd0\u884c\u60c5\u51b5\u4e0b\uff0c\u7528\u7535\u8bbe\u5907\u7aef\u5b50\u5904\u7535\u538b\u504f\u5dee\u5141\u8bb8\u503c\u5b9c\u7b26\u5408\u4e0b\u5217\u8981\u6c42:
1\u3001 \u7535\u52a8\u673a\u4e3a\u58eb5% \u989d\u5b9a\u7535\u538b\u3002
2\u3001 \u7167\u660e\uff1a\u5728\u4e00\u822c\u5de5\u4f5c\u573a\u6240\u4e3a\u58eb5% \u989d\u5b9a\u7535\u538b;\u5bf9\u4e8e\u8fdc\u79bb\u53d8\u7535\u6240\u7684\u5c0f\u9762\u79ef\u4e00\u822c\u5de5\u4f5c\u573a\u6240\uff0c\u96be\u4ee5\u6ee1\u8db3\u4e0a\u8ff0\u8981\u6c42\u65f6\uff0c\u53ef\u4e3a\u53415% \uff0c -10%\u989d\u5b9a\u7535\u538b;\u5e94\u6025\u7167\u660e\u3001\u9053\u8def\u7167\u660e\u548c\u8b66\u536b\u7167\u660e\u7b49\u4e3a+5% \uff0c -10% \u989d\u5b9a\u7535\u538b\u3002
3 \u3001\u5176\u4ed6\u7528\u7535\u8bbe\u5907\u5f53\u65e0\u7279\u6b8a\u89c4\u5b9a\u65f6\u4e3a\u58eb5% \u989d\u5b9a\u7535\u538b\u3002
\u4f60\u4e00\u770b\u5c31\u53ef\u4ee5\u77e5\u9053\u80fd\u5426\u6b63\u5e38\u4f7f\u7528\u3002

200kW\uff0c\u7535\u6d41\u7ea6400A\uff0c500\u7c73\u8ddd\u79bb\u6bd4\u8f83\u8fdc\uff0c\u7ebf\u8def\u635f\u5931\u538b\u964d\u5fc5\u987b\u8003\u8651\uff0c\u5efa\u8bae\u9009\u7528\uff1a
YJV-0.6/1 1X400 \u5355\u82af\u94dc\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u805a\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u6216\u8005
YJLV-0.6/1 1X500 \u5355\u82af\u94dd\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u805a\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u4f5c\u4e3a\u4e09\u76f8\u4e09\u6839\u76f8\u7ebf\u7535\u7f06\u3002
YJV-0.6/1 1X185 \u5355\u82af\u94dc\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u805a\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u6216\u8005
YJLV-0.6/1 1X240 \u5355\u82af\u94dd\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u805a\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u4f5c\u4e3a\u4e00\u6839\u96f6\u7ebf\u7535\u7f06
\u5982\u679c\u8d70\u5730\u4e0b\u571f\u58e4\u76f4\u57cb\u6577\u8bbe\uff1a\u5efa\u8bae\u9009\u7528\uff1a
YJV22-0.6/1 1X400 \u5355\u82af\u94dc\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u94a2\u5e26\u94e0\u88c5\u805a\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u6216\u8005
YJLV22-0.6/1 1X500 \u5355\u82af\u94dd\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u94a2\u5e26\u94e0\u88c5\u805a\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u4f5c\u4e3a\u4e09\u76f8\u4e09\u6839\u76f8\u7ebf\u7535\u7f06\u3002
YJV22-0.6/1 1X185 \u5355\u82af\u94dc\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u805a\u94a2\u5e26\u94e0\u88c5\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u6216\u8005
YJLV22-0.6/1 1X240 \u5355\u82af\u94dd\u82af\u4ea4\u8054\u805a\u4e59\u70ef\u7edd\u7f18\u94a2\u5e26\u94e0\u88c5\u805a\u6c2f\u4e59\u70ef\u62a4\u5957\u7535\u529b\u7535\u7f06\uff0c\u4f5c\u4e3a\u4e00\u6839\u96f6\u7ebf\u7535\u7f06
\u4e5f\u53ef\u4ee5\u5bf9\u5e94\u9009\u7528\u805a\u6c2f\u4e59\u70ef\u7edd\u7f18\u7535\u7f06VV\u3001VLV\u3001VV22\u3001VLV22\u578b\u3002

如果功率因数按照0.8来计算电压按照三相线电压380V,那么电流为473.5A
按照这个电流和长500M来计算
电压降为0.152V
双拼的话用120mm2的应该够了电压降为0.23V,95mm2的话比较悬。

设计电缆型号合理,实际安装时应注意将负荷进行拆分,电缆不能并联使用。 每米电压降与电缆截面有关。如1.5平电缆的电压降为18.9mv/M;150平为0.3mv/M;300平为0.19mv/M。

nh-yjv-(3*25+2*16)
纯国标的电缆能带42个电流。
你的电压我不知道,所以请自己计算了
nhyjv
0.6/1kv的
都没问题

  • 璐熻嵎绾250kW,绾胯矾闀500绫,闇鐢╕JV鐨勫澶ц鏍肩數缂,鍏跺帇闄嶆槸澶氬皯._鐧惧害...
    绛旓細濡傛灉鍔熺巼鍥犳暟鎸夌収0.8鏉ヨ绠楃數鍘嬫寜鐓т笁鐩哥嚎鐢靛帇380V锛岄偅涔堢數娴佷负473.5A 鎸夌収杩欎釜鐢垫祦鍜岄暱500M鏉ヨ绠 鐢靛帇闄嶄负0.152V 鍙屾嫾鐨勮瘽鐢120mm2鐨勫簲璇ュ浜嗙數鍘嬮檷涓0.23V锛95mm2鐨勮瘽姣旇緝鎮
  • 500绫抽暱涓夌浉鍥涚嚎閾濋挶185骞虫柟鐢电紗鏈澶х敤鐢甸噺鏄灏KW?
    绛旓細渚涚數鍗婂緞澶暱锛屾í鎴潰绉185mm²鐨勯摑璐ㄥ绾挎渶澶ц礋杞250鍗冪摝宸﹀彸銆璐熻嵎杩囧ぇ绾垮鑷磋矾鍘嬮檷澶ぇ锛屾弧璐熻嵎鐨勬儏鍐典笅锛岃礋杞戒袱绔緱鍒扮殑鐢靛帇澶綆銆
  • 鎴戠殑璐熻浇鏄250KW璇ョ敤澶氬ぇ鐨勭嚎,杩樻湁灏辨槸鍙樺帇鍣ㄧ璐熻浇鏈400绫,鍒版椂鍊欑數鍘...
    绛旓細浣庡帇380浼忎緵鐢靛崐寰勪竴鑸笉瓒呰繃500绫筹紝浣犺繖400绫崇殑璺濈瀵逛簬250鍗冪摝鐨勮礋杞芥湁鐐硅繙浜嗭紝濡傛灉鏄緢澶氬皬璐熻嵎鍑戝湪涓璧风殑锛岃繕鍕夊己鍙互锛屽鏋滄槸涓鍙板ぇ鐢靛姩鏈猴紝灏卞緢闅句簡銆傚洜涓轰綘瑕佽冭檻鍚姩鏃讹紝姝e父杩愯鏃剁殑鐢电紗鐢靛帇闄嶃傝繖涔堝ぇ鐨勮礋鑽风數缂嗕竴鏍逛笉澶熶簡锛岃嚦灏戜袱鏍瑰ぇ鎴潰銆傚鏋滃彲鑳界殑璇濇渶濂藉氨杩戝畨瑁呬竴鍙板彉鍘嬪櫒銆
  • 鎴戣礋璐e畨瑁呬竴涓柦宸ョ數婧愰」鐩,璁$畻璐熻嵎250kW,璺濈800绫宠繙,璇烽棶鎴戝簲璇ラ...
    绛旓細195mm2鐢电紗
  • 250kw闇瑕佸澶х殑鐢电紗
    绛旓細250鍗冪摝闇瑕3x300骞虫柟鐨勯摐鐢电紗銆備竴鑸緝澶х殑鍔ㄥ姏鐢ㄧ數寰堝繉璁充袱鏍圭數缂嗗苟鍒楄繍琛岀殑鎯呭喌锛屽挨鍏舵槸涓嶅悓绾垮緞銆佷笉鍚岄暱搴︾殑鐢电紗銆250KW婊璐熻嵎杩愯鏃剁數娴佽嚦灏戝湪500A宸﹀彸锛70鐢电紗鍦ㄦ槑鏁凤紙绌跨銆佽蛋绾挎Ы绛夎浇娴侀噺瑕佸亸灏忥級鏃堕暱鏈熻繍琛岀殑鍏佽杞芥祦閲忔墠234A銆傝繕鏈変负浜嗚澶囧畨鍏ㄥ彲闈狅紝浣犲彲浠ュ啀閫変竴鏍瑰悓瑙勬牸鍚岄暱搴︾殑鐢电紗骞跺垪杩愯...
  • 鍏充簬鐢电紗鍘嬮檷璁$畻鐨勬眰鍔
    绛旓細婊璐熻嵎250kW锛鐢垫祦澶х害500A锛孻JV 3*240+1*120鐢电紗锛屽湪绌烘皵涓暦璁撅紝杞芥祦閲忔槸416A锛屽湪鍦颁笅鐩村煁鏁疯399A锛屾樉鐒剁數缂嗙殑瑙勬牸鏄皬浜嗐傚鏋滆鐢电紗鍦ㄧ┖姘斾腑鏁疯锛屾柇璺櫒400A锛岄偅涔堣緭鐢垫渶澶ц礋鑽峰湪200kW宸﹀彸锛堟病鑰冭檻鐢靛帇闄嶏級銆備綘娌℃湁鎻愪緵250KW璐熻嵎鐨勮礋杞芥ц川銆傚鏋滄寜鐓х數缂400A鐨勮浇娴侀噺锛堣礋杞200kW锛夋潵鑰冭檻锛...
  • 鎴戠幇鍦ㄦ湁涓缁堢璐熻嵎涓250KW,鏈350绫宠窛绂,鐜板湪鎴戠敤涓夌浉鍥涚嚎閾滆姱鐢电紗...
    绛旓細350m鍙屽苟鏃=0.11494*0.35/2=0.02娆у 濡傞瀹氱數娴480A锛屽惎鍔ㄧ數娴佹寜6.5鍊嶇畻锛480*6.5=3120A锛屽惎鍔ㄦ椂鍦ㄨ繖娈电數缂嗕笂鐨勫帇闄=3120*0.02=62.4V锛岀害涓62V銆 62V/380V=0.164锛屽嵆16.4%锛岃礋杞戒晶鏈帴鐓ф槑绛夊鐢靛帇娉㈠姩鏁忔劅鐨璐熻嵎锛鍕夊己杩樺彲浠ュ惂锛堝浗鏍囷細涓嶅疁浣庝簬棰濆畾鐢靛帇鐨85%锛夈
  • 涓夌浉250kw璐熻浇闇閰嶅澶х殑鐢电紗?闀垮害鏈200绫宠繙
    绛旓細鏉′欢锛氫笁鐩250kW璐熻浇锛岄瀹氱數鍘380V/220V锛涗緵鐢佃窛绂200m銆傝ˉ鍏呮潯浠讹細绾胯矾鍔熺巼鍥犳暟鍙0.85锛屾湁鍔熼渶瑕佺郴鏁板彇1锛堢敱浜庢彁闂呮湭鎻愪緵姝250kW璐熻嵎鎬ц川鍙婄粺璁¤〃锛夈傝绠楃數娴侊細250/0.38/1.732/0.85=446.87A锛涙柇璺櫒閫夋嫨锛氬3鏋剁數娴630A锛屾柇璺櫒杩囪浇闀垮欢鏃舵暣瀹氬硷細446.87Ax1.1=491.56A锛屽彇500A锛涗緵鐢电數缂...
  • 鐢靛帇380V 璐熻浇250KW 闀垮害100M 瑕佺敤澶氬ぇ鐨勭數缂,鍙互鍛婅瘔鎴戞庝箞绠楀嚭瀵肩嚎...
    绛旓細鍔熺巼250kw鐨勯瀹氱數娴両=P/1.732Ucos桅=250/1.732/0.38/0.8=250/0.53=472瀹 閾滅數鐢电紗150骞虫柟姣背锛岄摑鐢电紗240骞虫柟姣背銆傞夋嫨瀵肩嚎蹇呴』婊¤冻鐨勫洓涓師鍒欙細1锛夎繎璺濈鍜屽皬璐熻嵎鎸夊彂鐑潯浠堕夋嫨瀵肩嚎鎴潰锛堝畨鍏ㄨ浇娴侀噺锛夛紝鐢ㄥ绾跨殑鍙戠儹鏉′欢鎺у埗鐢垫祦锛屾埅闈㈢Н瓒婂皬锛屾暎鐑秺濂斤紝鍗曚綅闈㈢Н鍐呴氳繃鐨勭數娴佽秺澶с2锛夎繙...
  • ,鎴戠幇鍦ㄦ湁涓缁堢璐熻嵎涓250KW,绂绘垜鐨勫彉鍘嬪櫒澶х害涓5鍏噷,鐜板湪鎴戠敤涓夌浉...
    绛旓細浣犲彧鑳芥兂鍔炴硶闄嶄綆绾挎崯鑰楋紝褰撴甯稿伐浣滅數娴佷负378A鏃舵瘡鏉$嚎缂嗘崯鑰133412W涓夋潯鎬绘崯鑰400KVA澶氫簡锛屼竴骞寸數鎹熻=24*400*365=3504000搴︾數浜嗭紝鎵浠ュ缓璁綘鎵句笂娴锋綐鐧绘柊鐢垫簮鏈夐檺鍏徃濮滅粡鐞嗭紝濂瑰凡缁忔垚鍔熶负濂藉嚑涓墦闅ч亾瀹㈡埛瑙e喅鍍忎綘绫婚毦棰樸 寤鸿浣犵敤240骞虫柟,鍐嶇敤涓婃捣娼樼櫥鏂扮數婧愭湁闄愬叕鍙告柟妗堟墠鏈夊彲鑳藉畬鎴....
  • 扩展阅读:电缆kw对照表 ... 150平方电缆对照表 ... 7.5千瓦水泵多少钱一台 ... 250kw配多大的电缆 ... 250kw多少平方的电缆 ... 250kw380v用多大电缆 ... 150铜电缆带多少kw ... 250kva变压器价格 ... 水泵型号及参数大全 ...

    本站交流只代表网友个人观点,与本站立场无关