低压380V,负荷电流已经计算出是600安,准备配五芯电缆,请问电缆型号截面积? 电缆截面积到几百,就肯定是低压吗?

\u7535\u7f06\u80fd\u8d1f\u8377\u7684\u7535\u6d41\u6709\u591a\u5c11\uff1f\u4e0e\u578b\u53f7\u5bf9\u5e94\u3002

\u5de5\u4f5c\u6e29\u5ea630\u2103\uff0c\u957f\u671f\u8fde\u7eed90\uff05\u8d1f\u8f7d\u4e0b\u7684\u8f7d\u6d41\u91cf\u5982\u4e0b\uff1a
1.5\u5e73\u65b9\u6beb\u7c73\u2015\u201518A
2.5\u5e73\u65b9\u6beb\u7c73\u2015\u201526A
4\u5e73\u65b9\u6beb\u7c73\u2015\u201526A
6\u5e73\u65b9\u6beb\u7c73\u2015\u201547A
10\u5e73\u65b9\u6beb\u7c73\u2015\u201566A
16\u5e73\u65b9\u6beb\u7c73\u2015\u201592A
25\u5e73\u65b9\u6beb\u7c73\u2015\u2015120A
35\u5e73\u65b9\u6beb\u7c73\u2015\u2015150A
\u529f\u7387P=\u7535\u538bU\u00d7\u7535\u6d41I\uff1d220\u4f0f\u00d718\u5b89\uff1d3960\u74e6
\u6807GB4706.1-1992/1998\u89c4\u5b9a\u7684\u7535\u7ebf\u8d1f\u8f7d\u7535\u6d41\u503c\uff08\u90e8\u5206\uff09
\u94dc\u82af\u7535\u7ebf:..\u94dc\u82af\u7ebf\u622a\u9762\u79ef.. \u5141\u8bb8\u957f\u671f\u7535\u6d41..2.5 \u5e73\u65b9\u6beb\u7c73(16A\uff5e25A)..
4\u5e73\u65b9\u6beb\u7c73(25A\uff5e32A)..6\u5e73\u65b9\u6beb\u7c73(32A\uff5e40A)
\u94dd\u82af\u7535\u7ebf:\u94dd\u82af\u7ebf\u622a\u9762\u79ef.. \u5141\u8bb8\u957f\u671f\u7535\u6d41..2.5 \u5e73\u65b9\u6beb\u7c73(13A\uff5e20A)
4\u5e73\u65b9\u6beb\u7c73( 20A\uff5e25A).. 6\u5e73\u65b9\u6beb\u7c73( 25A\uff5e32A)
\u94dc\u82af\u7535\u7ebf\u7535\u7f06\u8f7d\u6d41\u91cf\u6807\u51c6
\u7535\u7f06\u8f7d\u6d41\u91cf\u53e3\u51b3\uff1a
\u4f30\u7b97\u53e3\u8bc0\uff1a
\u4e8c\u70b9\u4e94\u4e0b\u4e58\u4ee5\u4e5d\uff0c\u5f80\u4e0a\u51cf\u4e00\u987a\u53f7\u8d70\u3002
\u4e09\u5341\u4e94\u4e58\u4e09\u70b9\u4e94\uff0c\u53cc\u53cc\u6210\u7ec4\u51cf\u70b9\u4e94\u3002
\u6761\u4ef6\u6709\u53d8\u52a0\u6298\u7b97\uff0c\u9ad8\u6e29\u4e5d\u6298\u94dc\u5347\u7ea7\u3002
\u7a7f\u7ba1\u6839\u6570\u4e8c\u4e09\u56db\uff0c\u516b\u4e03\u516d\u6298\u6ee1\u8f7d\u6d41\u3002

\u4f4e\u538b\u6216\u9ad8\u538b\u4e0d\u662f\u4ee5\u7535\u7f06\u622a\u9762\u79ef\u7684\u5927\u5c0f\u6765\u533a\u5206\u7684

型号和截面都需要根据敷设环境、敷设方式等因素查设计手册中相应的表格确定。但是3*120+2*95的铜芯电缆肯定不够,双拼都不一定够,具体还是得查表。
网上所谓的口诀只能供参考,正确的选择必须根据不同敷设条件查相应的表格,或根据规范计算(很麻烦)。

问题补充:低压380V,负荷电流已经是什么负载,如果电机负载按每千瓦2A

用3*120+2*95的铜芯电缆太小了,负载600A,一般考虑到环境温度及敷设方式要除以0.7,电流按照857A算,2根3*240+2*120的铜芯电缆才行,用一根的话,估计要到3*630+2*300的才行

这个问题有个前提,要看你的电缆是铝芯还是铜芯,铜芯载流量比铝芯大,如果用铝芯,根据电工口诀,600A,5跟放载流量就是300A,电缆5跟的口径不能小于150mm,但如果是铜芯的,3*120+2*95完全可以用

  • 浣庡帇380V,璐熻嵎鐢垫祦宸茬粡璁$畻鍑烘槸600瀹,鍑嗗閰嶄簲鑺數缂,璇烽棶鐢电紗鍨嬪彿鎴潰 ...
    绛旓細鍨嬪彿鍜屾埅闈㈤兘闇瑕佹牴鎹暦璁剧幆澧冦佹暦璁炬柟寮忕瓑鍥犵礌鏌ヨ璁℃墜鍐屼腑鐩稿簲鐨勮〃鏍肩‘瀹氥備絾鏄3*120+2*95鐨勯摐鑺數缂嗚偗瀹氫笉澶燂紝鍙屾嫾閮戒笉涓瀹氬锛屽叿浣撹繕鏄緱鏌ヨ〃銆傜綉涓婃墍璋撶殑鍙h瘈鍙兘渚涘弬鑰冿紝姝g‘鐨勯夋嫨蹇呴』鏍规嵁涓嶅悓鏁疯鏉′欢鏌ョ浉搴旂殑琛ㄦ牸锛屾垨鏍规嵁瑙勮寖璁$畻锛堝緢楹荤儲锛夈
  • 浣庡帇380V绾胯矾鐢垫祦澶氬皯A?
    绛旓細鐢垫祦鐨勫ぇ灏忕洿鎺ヤ笌鍔熺巼鏈夊叧锛屼篃涓庣數鍘嬨佺浉鍒佸姏鐜囷紙鍙堢О鍔熺巼鍥犳暟锛夌瓑鏈夊叧銆備竴鑸湁鍏紡鍙緵璁$畻銆傜敱浜庡伐鍘傚父鐢ㄧ殑閮芥槸380/220浼忎笁鐩稿洓绾跨郴缁燂紝鍥犳锛屽彲浠ユ牴鎹姛鐜囩殑澶у皬鐩存帴绠楀嚭鐢垫祦銆2銆佸彛璇 浣庡帇380/220浼忕郴缁熸瘡鍗冪摝鐨鐢垫祦锛瀹夈傚崈鐡︺佺數娴侊紝濡備綍璁$畻锛熺數鍔涘姞鍊嶏紝鐢电儹鍔犲崐銆傚崟鐩稿崈鐡︼紝4.5瀹夈傚崟鐩380...
  • 380V绯荤粺涓,鐭ラ亾璐熻嵎濡備綍璁$畻鐢垫祦?
    绛旓細杩橀渶瑕佺煡閬撳姛鐜囧洜鏁帮紝涓夌浉绾胯矾璐熻浇鐢垫祦鍏紡锛欼=P/1.732/U/鍔熺巼鍥犳暟
  • 濡備綍璁$畻鐢电紗鐨璐熻嵎(宸茬煡妯埅闈,杞芥祦閲)
    绛旓細鐢靛帇绛夌骇380V锛岄瀹氬姛鐜囨槸460KW锛屽伐浣鐢垫祦澶х害锛欼=460/锛1.732*0.38*0.8锛=874A 鐢ㄩ摑鑺數缂嗛夌敤闈㈢Н锛歋=874/1.2=728骞虫柟姣背 鏍规嵁閾濆绾胯鏍煎簲閫夌敤锛3鏍归摑鑺4X240鐨勭數缂嗗苟鑱斾娇鐢ㄣ
  • 鏈変竴鏉浣庡帇380V鏋剁┖绾胯矾闀垮害涓100M,鎵璐熻嵎涓60KW銆侰OS蠄=0.8褰撳湴鏈楂...
    绛旓細鏍规嵁鍏紡绠楀緱鐢垫祦I=P/(1.732*U*cos-p)=60000/(1.732*380*0.8)=114A 缁忛獙鍏紡绠楀緱50骞虫柟閾濊姱缂嗙嚎瀹夊叏杞芥祦绾150A,瀹屽叏鍙互璐熻浇60KW鐨勮澶囥傝嫢鑰冭檻绾垮帇闄嶇殑璇濓紝380V鐨勮澶囧厑璁稿帇闄20V宸ヤ綔锛屽垯姣忔牴绾垮帇闄嶄负10V,绾跨數闃籖=U/I=0.0877娆у 闇閰嶇殑閾濊姱鐢电紗妯埅闈㈢НS=0.0283*(L/R)=0.0283...
  • 璁$畻涓璐熻嵎鐢垫祦,鍦ㄧ嚎绛!!
    绛旓細220V 鐢ㄧ數鍣 椋庢墖 鎺掓皵鎵 椋庢満 鐓ф槑 鍐版煖 寰尝鐐 鎶芥补鐑熸満绛夛紝棰濆畾鍔熺巼鍏123KW (鐢靛櫒涓夌浉灏介噺鍧囧竷)姣忕浉澶х害锛123/3=41KW 380V 鐢ㄧ數鍣 鐐掔倝 钂稿寘鐐 绌鸿皟绛 棰濆畾鍔熺巼鍏憋細P=119KW+41=160KW 鎬璐熻嵎鐢垫祦锛欼=160/锛1.732*0.38*0.7锛=347A 閫夌敤鎬婚摐瀵肩嚎闈㈢Н锛歋=347/2=174骞虫柟姣背 鏍规嵁瀵肩嚎...
  • 10KV渚ч珮鍘,浣庡帇渚380V,浣庡帇璐熻嵎250KW,鐢ㄥ澶у閲忕殑鍙樺帇鍣,澶氬ぇ鎴潰鐨...
    绛旓細浣庡帇璐熻嵎250KW锛屽伐浣鐢垫祦鏄細475A 鍙樺帇鍣ㄧ殑瀹归噺涓嶅皬浜庯細S锛堣鍦ㄥ姛鐜囷級=1.732*0.4*475=329KVA 10KV楂樺帇渚э紝棰濆畾鐢垫祦锛欼1=329/锛1.732*10锛=19A 10KV楂樺帇渚ч夌敤瀵肩嚎闈㈢Н锛歋=19/3=6.3骞虫柟姣背鐨勯摐瀵肩嚎 鏍规嵁瀵肩嚎瑙勬牸楂樺帇渚у簲閫夌敤10骞虫柟姣背鐨勯摐瀵肩嚎 渚т綆鍘嬩晶380V锛棰濆畾鐢垫祦锛欼1=329/锛1.732...
  • 380V浣庡帇鐢靛鍣ㄦ煖鐨鐢垫祦濡備綍璁$畻?
    绛旓細800脳0.691锛553(鍗冧箯)姣忕浉棰濆畾鐢垫祦锛欼x锛漄c/1.732脳U (U锛濈數瀹瑰櫒棰濆畾鐢靛帇锛屼綆鍘鐢靛姏鐢靛鍣ㄧ殑棰濆畾鐢靛帇涓0.45KV)Ix锛553/1.732脳0.45鈮710(A)鏂矾鍣ㄥ疁閫夌敤800A锛屼笉杩囷紝涓鑸殑鐢靛鏌滄诲紑鍏抽夌敤闅旂寮鍏筹紝鑰屾瘡鍙數瀹瑰櫒鍧囬夌敤涓涓柇璺櫒锛屼互16鍗冧箯涓轰竴涓數瀹瑰櫒璁$畻锛棰濆畾鐢垫祦绾20.5A锛屽疁閫夌敤...
  • 380V涓夌浉鍥涚嚎鍒朵緵鐢电數璺腑,鐢垫祦濡備綍璁$畻?
    绛旓細1銆鐢垫祦I=宸茬煡鍔熺巼180KW/鐢靛帇380V=473.684A锛2銆佸绾跨數娴佺殑璁$畻锛氱數鍣ㄧ殑鍔熺巼W / 杈撳叆鐢靛帇V = 瀵肩嚎鐢垫祦A锛屽嵆锛473.684A锛涢噰鐢ㄤ笁鐩稿洓绾垮埗渚涚數锛屽簲璇ユ妸180KW骞冲潎鍒嗛厤鍒版瘡涓鐩镐笂锛屽嵆姣忕浉璐熻嵎涓180/3=60KW锛屼互涓婅绠楁槸鎸夌収绾樆鎬ц礋杞借绠楃殑銆傚鏋滈噰鐢ㄥ叾瀹冪被鍨嬬殑锛岄渶瑕佽冭檻鍔熺巼鍥犳暟鐨勫奖鍝嶏紝瀵硅绠楃粨鏋...
  • 宸ョ▼涓,璁$畻380V涓220V鐨鐢垫祦鏄庝箞绠楃殑??
    绛旓細鐢垫祦=鐢靛帇梅闃绘姉 锛堢數鍘嬩负380鎴220锛岄樆鎶²=鐢甸樆²锛嬬數鎶²锛夈傜瀛︿笂鎶婂崟浣嶆椂闂撮噷閫氳繃瀵间綋浠讳竴妯埅闈㈢殑鐢甸噺鍙仛鐢垫祦寮哄害锛岀畝绉扮數娴併傞氬父鐢ㄥ瓧姣 I琛ㄧず锛屽畠鐨勫崟浣嶆槸瀹夊煿锛堝畨寰风儓路鐜涗附路瀹夊煿锛1775骞粹1836骞达紝娉曞浗鐗╃悊瀛﹀銆佸寲瀛﹀锛屽湪鐢电浣滅敤鏂归潰鐨勭爺绌舵垚灏卞崜钁楋紝瀵规暟瀛﹀拰鐗╃悊涔熸湁璐$尞...