补偿导线故障时会着火吗

\u4ec0\u4e48\u662f\u8865\u507f\u5bfc\u7ebf\uff1f\u4e3a\u4ec0\u4e48\u8981\u91c7\u7528\u8865\u507f\u5bfc\u7ebf\uff1f\u76ee\u524d\u7684\u8865\u507f\u5bfc\u7ebf\u6709\u54ea\u51e0\u79cd\u7c7b\u578b\uff1f\u5728\u4f5c\u7528\u4e2d\u5e94\u6ce8\u610f\u54ea\u4e9b\u95ee\u9898\uff1f

\u3000\u3000\u8865\u507f\u5bfc\u7ebf\u4f5c\u7528\u7684\u5b9e\u8d28\u662f\u70ed\u7535\u5076\u7684\u5ef6\u957f
\u3000
\u3000\u3000\u70ed\u7535\u5076\u7684\u8865\u507f\u5bfc\u7ebf\u662f\u5728\u4e00\u5b9a\u6e29\u5ea6\u8303\u56f4\u5185\uff08\u5305\u62ec\u5e38\u6e290\uff09\u5177\u6709\u4e0e\u6240\u5339\u914d\u70ed\u7535

\u5076\u70ed\u7535\u52a8\u52bf\u76f8\u540c\u6807\u79f0\u503c\u7684\u4e00\u5bf9\u5e26\u6709\u7edd\u7f18\u5c42\u7684\u5bfc\u7ebf\uff0c\u7528\u4ed6\u4eec\u8fde\u63a5\u70ed\u7535\u5076\u4e0e\u6d4b\u91cf\u88c5

\u7f6e\uff0c\u76f8\u5f53\u4e8e\u5c06\u70ed\u7535\u5076\u5ef6\u957f\u5230\u6d4b\u91cf\u88c5\u7f6e\u3002
\u3000\u3000
\u3000\u3000\u7531\u4e8e\u201d\u70ed\u7535\u5076\u7684\u8865\u507f\u5bfc\u7ebf\u662f\u5728\u4e00\u5b9a\u6e29\u5ea6\u8303\u56f4\u5185\uff08\u5305\u62ec\u5e38\u6e290\uff09\u5177\u6709\u4e0e\u6240\u5339\u914d

\u70ed\u7535\u5076\u70ed\u7535\u52a8\u52bf\u76f8\u540c\u6807\u79f0\u503c\u7684\u4e00\u5bf9\u5e26\u6709\u7edd\u7f18\u5c42\u7684\u5bfc\u7ebf\u201c\uff0c\u5b83\u662f\u53ef\u4ee5\u5728\u4e00\u5b9a\u8303\u56f4

\u5185\u6784\u6210\u70ed\u7535\u5076\uff08\u5b9e\u9645\u4e0a\u8865\u507f\u578b\u7684\u8865\u507f\u5bfc\u7ebf\u548c\u540c\u5206\u5ea6\u70ed\u7535\u5076\u662f\u540c\u6750\u8d28\u7684\uff09\uff0c\u6839\u636e

\u70ed\u7535\u5076\u7684\u4e2d\u95f4\u5bfc\u4f53\u5b9a\u5f8b\u201c\u5728\u70ed\u7535\u5076\u56de\u8def\u4e2d\u63a5\u5165\u4e2d\u95f4\u5bfc\u4f53\uff08\u7b2c\u4e09\u5bfc\u4f53\uff09\u53ea\u8981\u4e2d\u95f4

\u5bfc\u4f53\u4e24\u7aef\u6e29\u5ea6\u76f8\u540c\uff0c\u4e2d\u95f4\u5bfc\u4f53\u7684\u5f15\u5165\u5bf9\u70ed\u7535\u5076\u56de\u8def\u603b\u7535\u52bf\u6ca1\u6709\u5f71\u54cd\u3002\u4e5f\u5c31\u662f\u8bf4

\u5728\u4e0d\u8ba1\u70ed\u7535\u5076\u7684\u5f71\u54cd\u65f6\uff0c\u8865\u507f\u5bfc\u7ebf\u4e5f\u53ef\u4ee5\u4ea7\u751f\u70ed\u7535\u52bf\uff0c\u5176\u5927\u5c0f\u7b49\u4e8e\u70ed\u7535\u5076\u5c3e\u7aef

\u4e0e\u6d4b\u91cf\u88c5\u7f6e\u4e4b\u95f4\u7684\u6e29\u5dee\u7535\u52bf\u3002
\u3000\u3000
\u3000\u3000\u6b63\u786e\u4f7f\u7528\u65f6\uff0c\u70ed\u7535\u5076\u7684\u7535\u52bf\u548c\u8865\u507f\u5bfc\u7ebf\u7535\u52bf\u53e0\u52a0\uff0c\u5728\u51b7\u70ed\u7aef\u6e29\u5ea6\u4e0d\u53d8\u7684\u60c5

\u51b5\u4e0b\uff0c\u968f\u7740\u70ed\u7535\u5076\u4e0e\u8865\u507f\u5bfc\u7ebf\u8fde\u63a5\u5904\u7684\u6e29\u5ea6\u53d8\u5316\uff0c\u70ed\u7535\u5076\u7684\u6e29\u5dee\u7535\u52bf\u589e\u5927\u8865\u507f

\u5bfc\u7ebf\u7684\u6e29\u5dee\u7535\u52bf\u51cf\u5c0f\uff0c\u53cd\u4e4b\u4ea6\u7136\uff0c\u8fbe\u5230\u8865\u507f\u70ed\u7535\u5076\u4e0e\u6d4b\u91cf\u88c5\u7f6e\u4e4b\u95f4\u7684\u6e29\u5ea6\u53d8\u5316

\u6240\u4ea7\u751f\u7684\u5f71\u54cd\u3002 \u6d4b\u91cf\u88c5\u7f6e\u6d4b\u5230\u7684\u662f\u70ed\u7535\u5076\u4ea7\u751f\u7684\u70ed\u7535\u52bf\u4e0e\u8865\u507f\u5bfc\u7ebf\u4ea7\u751f\u7684\u8865

\u507f\u7535\u52bf\u7684\u53e0\u52a0\u7535\u52bf\u3002
\u3000
\u3000\u3000\u8865\u507f\u5bfc\u7ebf\u5177\u6709\u548c\u70ed\u7535\u5076\u76f8\u540c\u7684\u5206\u5ea6\u53f7\u3002\u5176\u578b\u53f7\u9996\u5b57\u6bcd\u5373\u5206\u5ea6\u53f7\uff0c\u7b2c\u4e8c\u5b57\u6bcd

C\u4e3a\u8865\u507f\u578b\uff0cX\u4e3a\u5ef6\u957f\u578b \u5982 SC\uff0cKX\uff0cKC\uff0cEX\uff0cJX\uff0cTX\u3002

\u8865\u507f\u5bfc\u7ebf\u6709\u70ed\u7535\u52bf\u3002\u4f60\u7528\u7535\u538b\u6863\u91cf\uff0c\u94dc\u7ebf\u6ca1\u6709\u7535\u538b\uff0c\u8865\u507f\u5bfc\u7ebf\u6709\u7535\u538b\u3002\u4f60\u6362\u4e00\u4e0b\u8868\u7b14\u7684\u65b9\u5411\u6d4b\u91cf\u8865\u507f\u5bfc\u7ebf\uff0c\u6d4b\u91cf\u7ed3\u679c\u4f1a\u53d8\u3002\u4f60\u5c06\u8865\u507f\u5bfc\u7ebf\u7684\u4e00\u6bb5\u77ed\u63a5\uff0c\u5b83\u5c31\u662f\u70ed\u7535\u5076\u4e86\u3002

条件适合时会引发火灾,比如:控器在指示偏低时会指令加热元件拼命加热,造成过热。
补偿导线是在一定温度范围内(0~100℃)具有与所匹配热电偶热电动势相同标称值的一对带有绝缘层的导线,用它们连接热电偶与测量装置,以补偿它们与热电偶连接处的温度变化所产生的误差。
其他指标
1.绝缘电阻:当周围空气温度为15-35℃,相对湿度不超过80%时,补偿导线成品线芯间和线芯与屏蔽层间的绝缘。
2.绝缘层及护套机械性能:绝缘层和护套的抗拉强度≥12.5N/m㎡,伸长率≥125% 。
3.阻燃性能:根据用户所需可以符合GB12666-1990A、B、C
补偿导线及补偿电缆外形尺寸和计算重量
注:Ⅰ带屏蔽或铝塑复合带的电缆外径略大于无屏蔽层的电缆
Ⅱ即有分屏蔽也有总屏蔽的电缆外径略大于只有分屏蔽的电缆
Ⅲ只有总屏蔽的电缆外径略小于只有分屏蔽的电缆

  补偿导线有些故障会造成指示偏低,温控器在指示偏低时会指令加热元件拼命加热,造成过热,条件适合时会引发火灾。

  • 琛ュ伩瀵肩嚎鏁呴殰鏃朵細鐫鐏悧
    绛旓細鏉′欢閫傚悎鏃朵細寮曞彂鐏伨锛屾瘮濡傦細鎺у櫒鍦ㄦ寚绀哄亸浣庢椂浼氭寚浠ゅ姞鐑厓浠舵嫾鍛藉姞鐑紝閫犳垚杩囩儹銆傝ˉ鍋垮绾挎槸鍦ㄤ竴瀹氭俯搴﹁寖鍥村唴锛0~100鈩冿級鍏锋湁涓庢墍鍖归厤鐑數鍋剁儹鐢靛姩鍔跨浉鍚屾爣绉板肩殑涓瀵瑰甫鏈夌粷缂樺眰鐨勫绾匡紝鐢ㄥ畠浠繛鎺ョ儹鐢靛伓涓庢祴閲忚缃紝浠ヨˉ鍋垮畠浠笌鐑數鍋惰繛鎺ュ鐨勬俯搴﹀彉鍖栨墍浜х敓鐨勮宸傚叾浠栨寚鏍 1.缁濈紭鐢甸樆:褰撳懆鍥寸┖姘旀俯...
  • 琛ュ伩瀵肩嚎鐨勯摐鑺嚎鑳涓嶈兘褰撶數绾跨敤
    绛旓細澶у鏁伴兘涓嶈兘銆備竴浜涜ˉ鍋垮绾跨殑鐗规х敋鑷冲拰鐢电倝涓濈浉杩戯紝褰撶數绾夸細鐫鐏殑銆